Sewage discharge monitoring, sewage monitoring system KNF-400C is based on urban waste treatment station, sewage discharge, enterprise discharge and other water quality monitoring related requirements and research and development, strengthen the safety management of urban discharge to provide basis and support and research and development of water quality online monitoring system, Mainly for COD, ammonia nitrogen, PH, dissolved oxygen, turbidity, temperature and other water quality to implement online and early warning, the product adopts modular design, easy installation and maintenance, suitable for single point and large area distribution monitoring needs.
Overview of KNF-400C on-line monitoring system for wastewater quality:
KNF-400C is an on-line water quality monitoring system based on the relevant requirements of water quality monitoring such as urban garbage disposal station, sewage discharge and enterprise discharge, which provides the basis and support for strengthening the safety management of urban discharge. It mainly carries out on-line and early warning for the temperature, conductivity, turbidity, COD, ammonia nitrogen, PH and dissolved oxygen of water quality. The product adopts modular design, is easy to install and maintain, and is suitable for the monitoring needs of single point and large area distribution.
At the same time, based on the research and development, production and operation experience in water quality online terminal monitoring equipment, data acquisition and transmission, environmental monitoring and management system, Shenzhen Kenafu has a long-term, stable and effective solution for the monitoring characteristics of drinking water. The system can realize the digital management of the whole process of monitoring and analysis of drinking water, data acquisition and transmission, equipment anti-control, monitoring and early warning, etc., which promotes the informationization and modernization of water environment management and can comprehensively improve the management level.
Technical indicators of KNF-400C on-line monitoring system for sewage discharge water quality:
Parameter index | Measuring principle | measuring range | resolution ratio | precision | power consumption | data output | supply voltage | the protection grades |
dissolved oxygen | Fluorescence spectrophotometry | 0~20mg/L | 0.01mg/L | ±2%F.S. | About 0.5W | Rs485 | 12-24VDC | IP68 |
salinity | electrochemistry | 0~70PSU | 0.1mg/L | ±1.5%F.S. | - | Rs485 | 12-24VDC | IP68 |
PH | Glass electrode method | 0~14pH | 0.01pH | ±0.05pH | About 0.3W | Rs485 | 12-24VDC | IP68 |
ORP | Platinum electrode | 0~±1999mV | 1mV | 1mV | About 0.5W | Rs485 | 12-24VDC | IP68 |
temperature | thermocouple | 0~50℃ | 0.1℃ | ±0.5℃ | Inside the electrode | Rs485 | 12-24VDC | IP68 |
electrical conductivity | Conductivity cell method | 0~5000µS/cm | 1µS/cm | 1% | About 0.5W | Rs485 | 12-24VDC | IP68 |
COD | spectroscopic methodology | 0.3~5000mg/L | 0.01mg/L | ±5%F.S. | About 1.5W | Rs485 | 12-24VDC | IP68 |
turbidity | 90 scattered light | 0~1000NTU | 1NTU | ±2%F.S. | About 0.6W | Rs485 | 12-24VDC | IP68 |
ammonia nitrogen | Ion selection method | 0~1000mg/L | 0.1mg/L | ±5%F.S. | About 1.2W | Rs485 | 12-24VDC | IP68 |
Oil in water | Ultraviolet fluorescence method | 0~100PPM | 0.01PPM | ±5% | About 0.6W | Rs485 | 12-24DVC | IP68 |
Data reporting | The configurable reporting interval can be uploaded to the cloud through GPRS. | |||||||
data output | RS485(modbus-rtu protocol), 4G wireless output, NB | |||||||
Data storage | The display screen has a built-in 128MB memory chip, which can be inserted into a U disk to export data tables, and the cloud platform can also store export data tables. | |||||||
operating voltage | AC220V @DC12-24V | |||||||
display system | 7-inch touch LCD collector, built-in large-capacity storage U disk export, data calibration and compensation functions, curve drawing and alarm record inquiry. | |||||||
Protective box | It is equipped with radiation-proof coating, built-in power distribution system, data acquisition system and data transmission system, outdoor rain-proof, dust-proof and insect-proof functions, column hoop installation, and protective box size: 300 x 250 x 470 mm. | |||||||
Maintenance cycle | About 6-18 months or according to the actual situation on site. | |||||||
Monitoring (optional) | Haikang and fluorite monitoring access platforms can be selected, and the scene images can be monitored at any time. | |||||||
Cloud platform (optional) | Software works registration right, using Alibaba Cloud server, real-time collection, storage, and synchronous release of data to LED, display terminal, with PC, mobile, WeChat binding and early warning functions. Independent account background, with mobile APP | |||||||
Alarm (optional) | Optional remote alarm to realize wireless remote on-site alarm prompt. | |||||||
Software and certification | Have software registration certificate, ISO9001, ISO14001, measurement test report and CMA test report. |
Have a professional after-sales team to respond to you 24 hours a day. We are committed to producing the best quality products at the most competitive prices. Therefore, we sincerely invite all interested companies to contact us for more information.