Хорошая цена  онлайн

Подробная информация о продукции

Created with Pixso. Дом Created with Pixso. продукты Created with Pixso.
Детектор озона
Created with Pixso. Ultrasonic Oxygen Sensor UOS-100 – O₂ & Flow Measurement

Ultrasonic Oxygen Sensor UOS-100 – O₂ & Flow Measurement

Наименование марки: ONETEST
Номер модели: УОС-100
MOQ: 1 шт.
Время доставки: 5-10 рабочий день
Условия оплаты: Т/Т
Подробная информация
Место происхождения:
ШЭНЬЧЖЭНЬ
Документ:
Диапазон:
21%-95,6%ОБ.
разрешение концентрации:
0,1%
Точность:
±1,5% полной шкалы при (5–55) ℃
Диапазон обнаружения потока:
0-10L/min
Упаковывая детали:
КОРОБКА
Поставка способности:
300 штук+один месяц
Выделить:

Ultrasonic oxygen sensor with flow measurement

,

O₂ sensor for industrial use

,

UOS-100 oxygen detector with warranty

Характер продукции

1. Introduction of the ultrasonic oxygen sensor:
The UOS-100 ultrasonic oxygen concentration sensor uses an ultrasonic detection technology to measure the gas flow rate and oxygen concentration in the binary gas. With digital output, widely used in oxygen detector and oxygen generator, oxygen chamber, ventilator and other oxygen equipment.

Ultrasonic Oxygen Sensor UOS-100 – O₂ & Flow Measurement 0

2. product features 
1, using the principle of ultrasonic measurement, the gas concentration and oxygen flow can be measured simultaneously
2, small volume, fast response, stable measurement, high accuracy
3. Calibration before leaving the factory, without user calibration
4. Long life span (more than 5 years)
5, meet the requirements of CE and EMC certification, and meet the special requirements of medical occasions


3.Technical indicators

Oxygen concentration detection range

21%-95.6%VOL

Concentration resolution

0.1%

Concentration detection accuracy

±1.5%FS @(5 - 55)

Flow detection range

0-10L/min

Flow resolution

0.1L/min

Traffic detection accuracy

± 0.2 L/min or read 5% (if larger)

Sample gas requirements

Water removal (no condensation)

Dust filtration (<1 u m)

Detection cycle

0.5S

preheating time

Power-on can be measured, the 10S to achieve the basic accuracy

numeric output

9600 bps UART _ TTL: 3.3V (withstand 5V input)

analog output

0~2.5V (Custom required)

LED output

(Can be set up according to the requirements.)

Green: oxygen concentration> 82%

Yellow: 82%> Oxygen concentration> 50%

Red: 50%> oxygen concentration

In and out of the air direction

The band arrow indicates the direction

working temperature

5~55℃

storage temperature

-5~65℃

relative humidity

585%RH

maximum pressure

150 kPa

working power supply

DC 6.5-12V,50mA