For engineers specifying a radiation dose sensor for permanent facility installation, the critical requirements are consistent: stable long-term detection performance, standard industrial communication output, factory-traceable calibration, and reliable alarm capability — all in a compact wall-mounted package that integrates cleanly into existing monitoring infrastructure.
The CESTSEN RAD-S102 Fixed Nuclear Radiation Probe delivers on every requirement.
A radiation dose sensor is a fixed detection transducer that continuously measures the radiation dose rate in its surrounding environment — converting ionizing radiation energy into electrical signals expressed as dose rate values (μSv/h or mR/h). In fixed monitoring systems, the sensor probe operates as a permanently installed detection node, transmitting real-time data to host controllers, SCADA systems, or cloud platforms via standard industrial communication protocols.
Unlike portable survey meters used for spot checks, a radiation dose sensor provides uninterrupted 24/7 coverage at its installation point — eliminating the gaps in protection that manual measurement cannot avoid.
![]()
The RAD-S102 Fixed Nuclear Radiation Probe is developed by CESTSEN (Shenzhen WanYi Technology Co., Ltd.) using a thin-wall metal Geiger-Müller counter tube imported from the United States as its core sensing element. It is designed for permanent wall-mounted installation in hospitals, industrial facilities, security inspection systems, pharmaceutical factories, and research institutions.
The RAD-S102 outputs measurement data via RS485 Modbus protocol — the de facto standard for industrial system integration — and connects natively with the CESTSEN GM-R200 multi-point radiation monitoring host, supporting up to 25 probes per system.
| Parameter | Specification |
|---|---|
| Detectable Ray Types | Hard β, γ, X-rays |
| Sensor Type | Thin-wall metal Geiger-Müller tube (US imported) |
| Measurement Range | 0.08–2000 μSv/h |
| Accuracy | ±20% |
| Energy Range | β: 1 MeV–3 MeV / γ: 50 keV–3 MeV / X: 30 keV–3 MeV |
| Data Output | RS485 Modbus protocol |
| Measurement Units | mR/h, μSv/h, CPS (three selectable units) |
| Alarm Function | 2-level sound and light alarm |
| Operating Temperature | -20°C to 60°C |
| Power Supply | 12–24V DC |
| Operating Current | 25–70 mA |
| Installation | Wall-mounted |
| Dimensions | 170 × 92 × 47 mm |
| Certifications | CE, ISO 9001, ISO 14001 |
CESTSEN offers two complementary variants to match different application requirements:
| Feature | RAD-S102 | RAD-S102X |
|---|---|---|
| Sensor | Thin-wall metal GM tube (USA) | Energy compensation Geiger tube |
| Ray Types | Hard β, γ, X-rays | γ, X-rays |
| Measurement Range | 0.08–2000 μSv/h | 0.01–10 mSv/h |
| Sensitivity | ~1500 cpm/mR/h | ~1600 cpm/mR/h |
| Energy Response | β: 1–3 MeV / γ: 50 keV–3 MeV | 40 keV–1.5 MeV |
| Best For | Industrial NDT, customs, hospitals | X-ray rooms requiring flat energy response |
The thin-wall metal Geiger tube sourced from a leading American manufacturer delivers consistent sensitivity between units, stable performance across the full operating temperature range, and a service life suited to years of continuous facility monitoring without sensor replacement.
Standard RS485 Modbus protocol integrates the RAD-S102 directly with any PLC, SCADA, DCS, or building management system — and natively with the CESTSEN GM-R200 monitoring host. No proprietary drivers, no protocol converters, no additional integration cost.
The RAD-S102's 2-level sound and light alarm operates independently of the host controller — triggering immediately at the probe when radiation exceeds preset thresholds, regardless of network connectivity or host system status. Local personnel receive instant on-site warning without any communication delay.
Output in mR/h, μSv/h, or CPS — selectable to match host system requirements — eliminating unit conversion errors in data processing pipelines.
Every RAD-S102 ships fully calibrated against ONETEST Technology's in-house Co-60 and Cs-137 standard radioactive sources. No field calibration required. Mount, connect power and RS485, and begin monitoring immediately.
Hospital X-Ray and Radiology Rooms
Deploy RAD-S102 probes in diagnostic X-ray suites, fluoroscopy rooms, and adjacent staff areas to continuously verify radiation levels comply with national controlled area limits — with RS485 output feeding the hospital's radiation safety management system.
Industrial NDT Facilities
Monitor radiation at the perimeter of radiography bays during gamma source exposures. The RAD-S102's hard beta detection capability provides additional coverage for environments where beta-emitting contamination may also be present.
Customs and Security Inspection
Install at cargo X-ray operator workstations to continuously document that staff occupational dose rates remain within regulatory limits — with timestamped data records for compliance audit.
Pharmaceutical Factories
Monitor areas adjacent to isotope handling zones, providing real-time area surveillance and automatic alarm if shielding integrity is compromised.
Multi-Point Monitoring Networks
Connect multiple RAD-S102 probes to a single GM-R200 host — supporting up to 25 probes per system for comprehensive facility-wide coverage from one centralized controller.
For system integrators and facility engineers specifying a radiation dose sensor that combines a US-imported metal GM tube, standard RS485 Modbus integration, dual-level onboard alarm, three selectable measurement units, and factory calibration — the CESTSEN RAD-S102 is a technically complete and competitively priced solution.
Contact ONETEST Technology today for datasheet, integration documentation, and project pricing.
![]()