Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Radon Detector
Created with Pixso. RAD-S50 Radon Gas Sensor Silicon Detector 5-65535 Bq/m³ Static Diffusion UART I2C Output Indoor Monitoring

RAD-S50 Radon Gas Sensor Silicon Detector 5-65535 Bq/m³ Static Diffusion UART I2C Output Indoor Monitoring

Brand Name: CESTSEN
Model Number: RAD-S50
MOQ: 1 Piece
Delivery Time: 7-15 Working Days
Payment Terms: T/T
Detail Information
Place of Origin:
Shenzhen, China
Detector Type:
Silicon Detector
Measurement Object:
Radon Gas
Measurement Range:
5-65535 Bq/m³
Detection Sensitive Area:
100mm² (10×10mm)
Sensitivity:
0.027 Cph/[Bq/m³]
Detection Lower Limit:
≤5 Bq/m³
Background Count Rate:
≤0.05 Cph (Nitrogen)
Uncertainty:
≤10% After 120 Hours (K=2)
Measurement Time:
≥60 Min
Communication Method:
UART / I²C
Communication Rate:
9600 Bps / ≤400 KHz
Working Voltage:
3.0V
Power Consumption:
≤150μW
Working Temperature:
0℃ ~ +45℃
Working Humidity:
≤90% RH (+45℃)
Storage Temperature:
-25℃ ~ +65℃
External Dimensions:
60×60×21mm
Packaging Details:
Anti-static bag with foam protection, export-grade corrugated carton
Supply Ability:
5000 Pieces per Month
Highlight:

Radon gas sensor with UART output

,

Silicon radon detector for indoor monitoring

,

Static diffusion radon sensor 5-65535 Bq/m³

Product Description

RAD-S50 Radon Gas Sensor — Precision Silicon Detector for Continuous Indoor Radon Monitoring

Shenzhen, China — The RAD-S50 is a high-performance radon gas sensor module engineered by Wanyi Technology (brand: CESTSEN) for long-term continuous monitoring of radon concentration in indoor environments. Featuring a large-area silicon detector with static diffusion sampling, the RAD-S50 delivers reliable measurements across a wide dynamic range from 5 to 65,535 Bq/m³ with exceptional sensitivity of 0.027 cph/[Bq/m³].

RAD-S50 Radon Gas Sensor Silicon Detector 5-65535 Bq/m³ Static Diffusion UART I2C Output Indoor Monitoring

Product Overview

The RAD-S50 radon detector measures radon gas concentration through the principle of static diffusion. By leveraging the radioactive properties of radon gas and its decay products, the sensor acquires alpha counts via a high-performance silicon detector (100mm² sensitive area, 10*10mm) and an advanced signal acquisition system. The integrated algorithm calculates precise radon concentration values, achieving continuous, unattended environmental monitoring with minimal power consumption.

Key Features

Feature Benefit
High-Sensitivity Silicon Detector 100mm² large-area detector with 0.027 cph/[Bq/m³] sensitivity ensures accurate low-concentration measurement down to ≤5 Bq/m³.
Static Diffusion Sampling No pump, no fan — simplified system design with zero moving parts, reducing maintenance and improving long-term reliability.
Humidity-Insensitive Design Measurement system is not sensitive to humidity variations, ensuring stable readings in diverse indoor environments.
Ultra-Low Power Consumption Operating at just 3.0V with ≤150μW power draw, ideal for battery-powered IoT devices and remote monitoring stations.
Dual Communication Interface Supports both UART (9600 bps) and I²C (≤400 kHz) protocols for flexible MCU integration.
Compact Form Factor Ultra-compact 60*60*21mm dimensions enable seamless integration into space-constrained devices and portable instruments.

Technical Specifications

Parameter Specification
Detector Type Silicon Detector
Measurement Object Radon Gas (²²²Rn)
Measurement Range 5 – 65,535 Bq/m³
Detection Sensitive Area 100mm² (10*10mm)
Sensitivity 0.027 cph/[Bq/m³] (0.982 cph/[pCi/L])
Detection Lower Limit ≤5 Bq/m³
Background Count Rate ≤0.05 cph (Nitrogen atmosphere)
Uncertainty ≤10% after 120 hours (K=2, radon concentration >200 Bq/m³)
Measurement Time ≥60 min (configurable)
Working Voltage 3.0V DC
Power Consumption ≤150μW
Communication Method UART (9600 bps) / I²C (≤400 kHz)
Working Environment 0℃ ~ +45℃, ≤90% RH (+45℃)
Storage Environment -25℃ ~ +65℃, ≤90% RH (+45℃)
External Dimensions 60 * 60 * 21 mm

Application Fields

  • Indoor Radon Measurement: Continuous static radon monitoring in residential, office, and public buildings for health risk assessment.
  • Environmental Radiation Monitoring: Long-term background radon surveys in geological, mining, and construction sites.
  • IoT Sensor Networks: Integration into wireless sensor nodes for distributed indoor air quality monitoring systems.
  • Laboratory Research: Radon gas behavior studies, material emission testing, and calibration reference measurements.
  • Smart Building Systems: Embedded radon sensor for active HVAC control and ventilation optimization in green buildings.

Why Choose RAD-S50?

The RAD-S50 stands out with its exceptional balance of high sensitivity, ultra-low power consumption, and compact design. Unlike pump-based radon monitors that require regular maintenance, the passive static diffusion method ensures years of trouble-free operation. The dual UART/I²C interface provides plug-and-play compatibility with popular MCU platforms including Arduino, ESP32, STM32, and Raspberry Pi. Adjustable parameters allow customization of measurement intervals, alarm thresholds, and data output formats to meet diverse application requirements.

Packing & Delivery

Each RAD-S50 sensor module is packaged in an anti-static protective bag with foam cushioning and shipped in export-grade corrugated cartons. Minimum order quantity: 1 piece. Supply capacity: 5,000 pieces per month. Delivery time: 3-10 working days. Payment accepted via T/T, For bulk orders, OEM customization, or technical inquiries, please contact Wanyi Technology (Shenzhen, China).