OZONE-300 LN series fixed ozone analyzer is designed and manufactured according to the verification and calibration method of the national environmental standard of the People's Republic of China-ultraviolet photometry method, and "ozone and ozone Generator for Water Treatment" of the Ministry of Construction of the People's Republic of China. The current ozone concentration is calculated by measuring the change of optical signal intensity before and after the absorption of ultraviolet light. Equipment using advanced double light road ultraviolet light source system, equipped with lamp intelligent management system, after boot can make the ultraviolet lamp quickly to measurement status, using foreign separation light pool technology, equipment has no leakage, high pressure resistance, large flow sampling gas impact, easy to clean, easy maintenance, simple operation, low use cost, etc. It is mainly used for continuous detection of ozone gas in various industrial environments, and can also be used for detection of ozone gas in pipelines, containers and other environments in operation. Widely used in pharmaceutical, chemical, municipal, sewage treatment and other industries, the ozone generator export concentration and ozone generator output measurement.
The ozone analyzer has a touch screen operation interface to display the concentration of ozone gas in real time, with pressure and temperature compensation and display, and can set the automatic zero calibration time and manual zero calibration mode.high concentration (g/Nm3) Range is equipped with flow input function, which can display the output of ozone generator in real time. With two sets of relay signal output, the user can freely choose the high alarm point and low alarm point signal output connection. The core component adopts ultraviolet long life light source system and high light transmittance quartz sheet to ensure the stability of zero point and prevent zero point drift from affecting the accuracy of detection concentration. According to the independent optical tank structure of pressure resistant and impact resistant designed by foreign optical tank technology, the gas flow, pressure and flow rate remain unchanged during the zero operation, so as to prevent the impact of the air zero. The zero operation can be completed without closing the ozone intake, ensuring that the equipment can run continuously for 24 hours a day.
Application fields: ozone generator manufacturers, municipal water industry, industrial sewage industry, fine chemical industry food and drinking water industry, space disinfection industry, swimming pool disinfection industry, essence synthesis industry and other ozone generator industry.
![]()
2. Product characteristics
Test method: dual-light path ultraviolet light absorption method, long-life light source system, high measurement accuracy.
Measurement principle: according to the Lambert-Beer law, accurate measurement through the luminosity absorption principle.
Light source system: foreign long-life ultraviolet light source system (wavelength 253.7nm), free warranty for 3 years.
Usage mode: indoor installation and use, equipped with power supply and signal terminals.
Optical pool system: separated optical pool technology, no leakage, high pressure resistance, large flow rate sampling gas impact.
Intelligent compensation: built-in temperature and pressure compensation and display, with light source automatic compensation function.
Operation mode: the user can select the manual zero calibration and automatic zero calibration according to the running status, and the automatic zero calibration time can be set.
Display units: g / Nm 3, mg / NL,% WT, ppm, mg / Nm 3 are optional.
Data display: high-definition color touch screen, high concentration range set into the gas mass flow rate, real-time display of output.
Output function: 4-20 mA, RS485 communication, two groups of alarm point output, electronic flowmeter input, etc.
Standard configuration: anti-corrosion flowmeter, ozone exhaust destroyer, air intake filter.
OZONE-300 LN series stationary ozone analyzer, optional range and working mode.
|
range |
Sampling method |
application area |
|
0-300g/Nm3 |
Positive pressure sampling, with pressure, and temperature compensation |
Real-time detection of ozone generator outlet concentration. |
|
0-100g/Nm3 |
Positive pressure sampling, with pressure, and temperature compensation |
Real-time detection of ozone generator outlet concentration. |
|
0-50g/Nm3 |
Sampling at positive or negative pressure, with pressure, and temperature compensation |
Ozone generator outlet or exhaust gas ozone concentration detection. |
|
0-1000ppm |
Sampling at positive or negative pressure, with pressure, and temperature compensation |
Real-time detection of ozone concentration in the box. |
3.Qualification
Model: OZONE-300 LN series
Measuring range: 0-300g / Nm3Built-in customizable
Optional range: 0-200g / Nm3,0-100g/Nm3,0-50g/Nm3,0-1000ppm,
Light source life: about 30,000-50,000 hours;
Sampling method: positive pressure sampling, negative pressure sampling (optional);
Display interface: 4.3-inch touch screen operation interface;
Content interface: ozone concentration, temperature, and pressure;
Auxiliary functions: temperature compensation, pressure compensation;
Display unit: g / Nm3,mg/NL,%WT,ppm ,mg/Nm3selectable;
Display resolution: 0.01 g/m3,0.01ppm;
Gas flow rate: 0.5L±0.2L/min;
Input pressure: <0.1MPa;
Concentration error: maximum 0.3%FS;
Linear error: maximum 0.2%FS;
Zero-point drift: <± 0.3%.FS;
Reaction time: 0.03 seconds, 0.3 seconds;
Ambient temperature: -20~50℃;
Line interface mode: quick twist (stainless steel);
Tandem sample diameter: Φ 8 (8mm * 6mm) (optional);
Bypass sampling diameter: Φ 6 (6mm * 4mm);
Communication mode: RS-485;
Output mode: 4-20 mA (active);
Telecom signal: high alarm point following electrical signal, low alarm point following electrical signal;
Power supply: AC 110-220V;
Dimensions: 230mm (height) 330mm (W) 150mm (deep);
Note: 1 mg/L = 1 g/m3 = 467 PPM;
Free warranty: 24 months (host);
Note: Standard configuration (built-in): flowmeter, ozone tail gas catalyst, air intake filter.